Solar Calculator Canada

Solar Power Calculator for Stratford, Prince Edward Island, Canada

Solar Output Report

The reports were generated based on 100 kWp solar system as it is easier to calculate any other size based on the results.

Location:
  • Location: Stratford
  • GPS Coordinates: 46.217778, -63.080833
  • Elevation: 28 m
Solar Installation Info:
  • Total installed power: 100 kWp
  • Solar panel technoloty: c-Si
  • Installation: Fixed
  • Optimal solar panel angle for Stratford: 36o
  • Average yearly irradiance: 1354.73 kWh/m2
  • Average yearly power output: 114833 kWh
Sun Path Stratford

Average yearly irradiance delivered by the Sun in Stratford is 1354.73/kWh/m2 at the optimal panel slope of 36o. After taking all losses into account, you can expect about 114833 kWh for every 100 kWp installed solar panels.

Solar irradiance and output report at optimal angle - 36o

Solar irradiance

Month Average Daily kWh/m2/d Average Monthly kWh/m2/mo
January 1.74 54.01
February 2.4 67.14
March 3.49 108.25
April 4.66 139.89
May 5.15 159.74
June 5.16 154.81
July 5.49 170.05
August 5.41 167.64
September 4.56 136.94
October 3.18 98.68
November 1.96 58.78
December 1.25 38.81
Total yearly 1354.73

Solar power output

Month Average Daily kWh/d Average Monthly kWh/mo
January 160.06 4961.8
February 219.81 6154.6
March 314.3 9743.21
April 406.24 12187.3
May 434.37 13465.5
June 423.54 12706.3
July 441.91 13699.3
August 437.69 13568.5
September 379.1 11373
October 271.94 8430.27
November 170.62 5118.61
December 110.46 3424.23
Total yearly 114833

Solar power output reports at other common angles

As it is not always possible to install the solar panels at the optimum angle, we calculated some more options so you can get a better idea of the difference. A 3/12 roof pitch corresponds to about 14o slope so the result should be just a bit below the 15o output. 4/12 roof pitch(18.4o) fals between 15o and 20o. 5/12 pitch is 22.6o, 6/12 is 26.6o, 7/12 is 30.3o etc...

Stratford solar output calculated at 15o

Month Average Daily kWh/d Average Monthly kWh/mo
January 121.85 3777.5
February 180.25 5046.98
March 285.31 8844.48
April 397.72 11931.5
May 450.76 13973.5
June 450.91 13527.4
July 463.94 14382.2
August 436.63 13535.6
September 349.35 10480.6
October 231.64 7180.73
November 134.36 4030.69
December 84.45 2617.89
Total yearly 109329

Solar power generation calculated at 20o

Month Average Daily kWh/d Average Monthly kWh/mo
January 132.7 4113.72
February 191.94 5374.42
March 295.07 9147.13
April 403.21 12096.2
May 450.29 13958.9
June 447.33 13420
July 461.84 14317.2
August 440.57 13657.6
September 359.89 10796.8
October 243.87 7559.83
November 144.76 4342.88
December 91.84 2846.94
Total yearly 111632

Solar power output calculated at 25o

Month Average Daily kWh/d Average Monthly kWh/mo
January 142.49 4417.19
February 202.28 5663.87
March 303.09 9395.76
April 406.56 12196.7
May 447.51 13872.7
June 442.01 13260.3
July 457.93 14195.8
August 442.11 13705.5
September 368.29 11048.6
October 254.52 7889.97
November 154.12 4623.71
December 98.52 3054
Total yearly 113324

Stratford Solar generation calculated at 30o

Month Average Daily kWh/d Average Monthly kWh/mo
January 151.2 4687.06
February 211.23 5914.47
March 309.34 9589.4
April 407.77 12233.1
May 442.55 13719
June 434.37 13031
July 451.49 13996.3
August 441.41 13683.7
September 374.51 11235.2
October 263.54 8169.8
November 162.4 4872.02
December 104.46 3238.4
Total yearly 114369

Looking for a different report? Feel free to drop us a line and we will get back to you ASAP.

Solar panels on a pole

Solar power calculation notes:

We made a few assumptions when making the above solar power output calculations.

Losses: The numbers in the reports take into account 10% technological losses based on the electrical parts of a solar installation. There are also -2.96% angle of incidence loss and -2.95% temperature and irradiance loss. This totals to about -15.24%%.

Location: We do not know your exact location so we can not take into account your surroundings, the elevation and terrain specifics. The solar power output calculations are based on panels being optimally facing the sun in the optimal case or uniformly faced South in the other cases.

Errors: Please keep in mind that although we did our best, the information presented here might contain errors. As such, please contact a local solar installer for individual report based on your exact location.

Solar panel degradation: Solar panels loose efficiency over time. The reports are valid for the initial panel installation. Most solar panel manufacturers guarantee 80% generation after 25 years.

More locations:

Murdochville